20 research outputs found

    Spider surgical system versus multiport laparoscopic surgery. Performance comparison on a surgical simulator

    Get PDF
    BACKGROUND: The rising interest towards minimally invasive surgery has led to the introduction of laparo-endoscopic single site (LESS) surgery as the natural evolution of conventional multiport laparoscopy. However, this new surgical approach is hampered with peculiar technical difficulties. The SPIDER surgical system has been developed in the attempt to overcome some of these challenges. Our study aimed to compare standard laparoscopy and SPIDER technical performance on a surgical simulator, using standardized tasks from the Fundamentals of Laparoscopic Surgery (FLS). METHODS: Twenty participants were divided into two groups based on their surgical laparoscopic experience: 10 PGY1 residents were included in the inexperienced group and 10 laparoscopists in the experienced group. Participants performed the FLS pegboard transfers task and pattern cutting task on a laparoscopic box trainer. Objective task scores and subjective questionnaire rating scales were used to compare conventional laparoscopy and SPIDER surgical system. RESULTS: Both groups performed significantly better in the FLS scores on the standard laparoscopic simulator compared to the SPIDER. Inexperienced group: Task 1 scores (median 252.5 vs. 228.5; p = 0.007); Task 2 scores (median 270.5 vs. 219.0; p = 0.005). Experienced group: Task 1 scores (median 411.5 vs. 309.5; p = 0.005); Task 2 scores (median 418.0 vs. 331.5; p = 0.007). Same aspects were highlighted for the subjective evaluations, except for the inexperienced surgeons who found both devices equivalent in terms of ease of use only in the peg transfer task. CONCLUSIONS: Even though the SPIDER is an innovative and promising device, our study proved that it is more challenging than conventional laparoscopy in a population with different degrees of surgical experience. We presume that a possible way to overcome such challenges could be the development of tailored training programs through simulation methods. This may represent an effective way to deliver training, achieve mastery and skills and prepare surgeons for their future clinical experience

    Learning curve for laparoscopic sleeve gastrectomy. Role of training in a high-volume bariatric center

    No full text
    Background Since the great diffusion of laparoscopic treatment of obesity, there is a growing interest concerning the learning process for those surgeons who undertake the bariatric activity. However, papers analyzing the learning curve (LC) for sleeve gastrectomy (SG) are still scarce. This study aims to investigate whether the LC for SG of a novice bariatric surgeon might be positively influenced by the training in a high-volume bariatric center (HVBC). Methods Between October 2010 and January 2014, 128 patients underwent SG by the same young surgeon who previously attended a 2-year training in a HVBC. His LC has been divided into three consecutive periods: in the first period (1st–47th SGs) he operated in the HVBC, while in the second (48th–88th SGs) and third period (89th–128th SGs) he moved to a novel department where surgical and ancillary staff were initially not confident with bariatric procedures but progressively owned the proper experience. Preoperative characteristics, operative data, complications and postoperative results of the three periods were compared. Results Mean follow-up was 1 year. Preoperative patients’ characteristics were homogeneous. No significant differences have been registered among the three periods concerning operative data, mortality, intra- and post-operative complications, weight loss outcomes and comorbidities’ resolution. Post-operative follow-up rates at 6 and 12 months were 98.4 and 92.1 %, respectively. Conclusions Long-lasting fellowship in a HVBC might allow the novel bariatric surgeon to safely and proficiently overcome the LC for SG, even in a new established bariatric setting

    Liver metastases: contrast-enhanced ultrasound compared with computed tomography and magnetic resonance

    No full text
    The development of ultrasound contrast agents with excellent tolerance and safety profiles has notably improved liver evaluation with ultrasound (US) for several applications, especially for the detection of metastases. In particular, contrast enhanced ultrasonography (CEUS) allows the display of the parenchymal microvasculature, enabling the study and visualization of the enhancement patterns of liver lesions in real time and in a continuous manner in all vascular phases, which is similar to contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging. Clinical studies have reported that the use of a contrast agent enables the visualization of more metastases with significantly improved sensitivity and specificity compared to baseline-US. Furthermore, studies have shown that CEUS yields sensitivities comparable to CT. In this review, we describe the state of the art of CEUS for detecting colorectal liver metastases, the imaging features, the literature reports of metastases in CEUS as well as its technique, its clinical role and its potential applications. Additionally, the updated international consensus panel guidelines are reported in this review with the inherent limitations of this technique and best practice experiences

    The Pyramidal Lobe of the Thyroid

    No full text
    Anatomy of the thyroid has been extensively studied but the presence of pyramidal lobe varies in percentages from 15% to 75% of cases according to different authors. We therefore investigated systematically this peculiar anatomical aspect. From January 2001 to December 2011, 1002 patients underwent total thyroidectomy in our Division of General Surgery. We analyzed the data collected on the latest 200 thyroidectomies: for all patients pyramidal lobe was measured at removal of the specimen then dimension of the pyramidal lobe after fixation was checked. We found the pyramidal lobe in all cases. In most cases, it was approximately 2 cm (range 1 - 8 cm on fresh specimen). At histology it was described in 72% of cases, after fixation size decreased by a third approximatively. This is the first systematic intraoperative study to verify the prevalence of the thyroid pyramidal lobe. In our experience, the pyramidal lobe is always present and the thyroglossal duct is identifiable

    Metastatic signet ring cell carcinoma presenting as a thyroid diffuse involvement: report of a case studied with Q-elastographic and acoustic radiation force impulse imaging features

    No full text
    Metastatic carcinomas to the thyroid are rare in daily clinical practice. However, when encountered they represent a diagnostic challenge, since it is difficult to distinguish them from primary thyroid lesions, especially when occurring in patients with occult malignant history. Nevertheless, it is critical to differentiate a metastatic tumor from primary thyroid lesions, as the clinical management and the prognosis are different for the two entities. More recently, elastosonography opened new possibilities to ultrasound in different fields, such as thyroid nodule differentiation. Herein, we report a case of metastatic signet ring cell carcinoma to the thyroid studied with quantitative elastography and acoustic radiation force impulse imaging
    corecore